TY - JOUR
T1 - Airway management at floor level
T2 - a comparison of tracheal intubation using the Macintosh and Airtraq laryngoscopes
AU - Tong, TL
AU - Gait, AJ
AU - Woollard, Malcolm
AU - Nightingale, PG
AU - Sharma, MR
N1 - Imported on 12 Apr 2017 - DigiTool details were: Journal title (773t) = Journal of the Royal Army Medical Corps. ISSNs: 0035-8665;
PY - 2008
Y1 - 2008
N2 - Practitioners providing pre-hospital care during civilian practice and on military operations may be required to perform airway management and tracheal intubation at floor level. It has been shown that intubation using the Airtraq laryngoscope is easier to learn than standard Macintosh laryngoscopy. We hypothesised that the Airtraq would be easier to use and have shorter intubation times than Macintosh intubation. Sixty volunteers attending a medical conference with no prior Airtraq experience, who were skilled in pre-hospital Macintosh intubation, were recruited. Each was required to intubate an anatomically correct manikin at floor level using a Macintosh and Airtraq laryngoscope. The Airtraq was found to be superior in ease of use (VAS 30 mm, P < 0.001), had a shorter total intubation time (19.4seconds) and a higher intubation success rate (P = 0.012) than the Macintosh laryngoscope (VAS 50 mm, 20.4 seconds). Rotating the tracheal tube 90 degrees anticlockwise during loading into the guiding channel, made the Airtraq intubation easier (VAS 30 mm, P = 0.001) and faster (19.4 seconds, P < 0.001) than with standard orientation of the tube (VAS 40 mm, 25.3 seconds). Airtraq intubation may prove to be easier than Macintosh intubation, when utilised in the clinical pre-hospital setting, though randomised controlled clinical trials are required to confirm this.
AB - Practitioners providing pre-hospital care during civilian practice and on military operations may be required to perform airway management and tracheal intubation at floor level. It has been shown that intubation using the Airtraq laryngoscope is easier to learn than standard Macintosh laryngoscopy. We hypothesised that the Airtraq would be easier to use and have shorter intubation times than Macintosh intubation. Sixty volunteers attending a medical conference with no prior Airtraq experience, who were skilled in pre-hospital Macintosh intubation, were recruited. Each was required to intubate an anatomically correct manikin at floor level using a Macintosh and Airtraq laryngoscope. The Airtraq was found to be superior in ease of use (VAS 30 mm, P < 0.001), had a shorter total intubation time (19.4seconds) and a higher intubation success rate (P = 0.012) than the Macintosh laryngoscope (VAS 50 mm, 20.4 seconds). Rotating the tracheal tube 90 degrees anticlockwise during loading into the guiding channel, made the Airtraq intubation easier (VAS 30 mm, P = 0.001) and faster (19.4 seconds, P < 0.001) than with standard orientation of the tube (VAS 40 mm, 25.3 seconds). Airtraq intubation may prove to be easier than Macintosh intubation, when utilised in the clinical pre-hospital setting, though randomised controlled clinical trials are required to confirm this.
KW - Airtraq
KW - Airway management
M3 - Article
SN - 0035-8665
VL - 154
SP - 21
EP - 25
JO - Journal of the Royal Army Medical Corps
JF - Journal of the Royal Army Medical Corps
IS - 1
ER -