Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing

Craig S. McLachlan, Herbert Jelinek, Sarah K Kummerfeld, Nicole Rummery, Patricia Jusuf, Brett Hambly, Mark A McGuire

Research output: Contribution to journalArticle

Original languageEnglish
Pages (from-to)122-123
Number of pages2
JournalRedox Report
Volume5
Issue number2
Publication statusPublished - 2000

Cite this

McLachlan, C. S., Jelinek, H., Kummerfeld, S. K., Rummery, N., Jusuf, P., Hambly, B., & McGuire, M. A. (2000). Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing. Redox Report, 5(2), 122-123.
McLachlan, Craig S. ; Jelinek, Herbert ; Kummerfeld, Sarah K ; Rummery, Nicole ; Jusuf, Patricia ; Hambly, Brett ; McGuire, Mark A. / Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing. In: Redox Report. 2000 ; Vol. 5, No. 2. pp. 122-123.
@article{7784ae703a0242a1a3e82086a10b58e6,
title = "Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing",
author = "McLachlan, {Craig S.} and Herbert Jelinek and Kummerfeld, {Sarah K} and Nicole Rummery and Patricia Jusuf and Brett Hambly and McGuire, {Mark A}",
note = "Imported on 12 Apr 2017 - DigiTool details were: Journal title (773t) = Redox Report. ISSNs: 1351-0002;",
year = "2000",
language = "English",
volume = "5",
pages = "122--123",
journal = "Redox Report",
issn = "1351-0002",
publisher = "Maney Publishing",
number = "2",

}

McLachlan, CS, Jelinek, H, Kummerfeld, SK, Rummery, N, Jusuf, P, Hambly, B & McGuire, MA 2000, 'Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing', Redox Report, vol. 5, no. 2, pp. 122-123.

Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing. / McLachlan, Craig S.; Jelinek, Herbert; Kummerfeld, Sarah K; Rummery, Nicole; Jusuf, Patricia; Hambly, Brett; McGuire, Mark A.

In: Redox Report, Vol. 5, No. 2, 2000, p. 122-123.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Cross-sectional infarct edge jaggedness does not influence ventricular electrical stability in a rabbit model of late myocardial infarct healing

AU - McLachlan, Craig S.

AU - Jelinek, Herbert

AU - Kummerfeld, Sarah K

AU - Rummery, Nicole

AU - Jusuf, Patricia

AU - Hambly, Brett

AU - McGuire, Mark A

N1 - Imported on 12 Apr 2017 - DigiTool details were: Journal title (773t) = Redox Report. ISSNs: 1351-0002;

PY - 2000

Y1 - 2000

M3 - Article

VL - 5

SP - 122

EP - 123

JO - Redox Report

JF - Redox Report

SN - 1351-0002

IS - 2

ER -