TY - JOUR
T1 - International survey on D-dimer test reporting
T2 - a call for standardization
AU - Lippi, Giuseppe
AU - Tripodi, Armando
AU - Simundic, Ana-Maria
AU - Favaloro, Emmanuel J
N1 - Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
PY - 2015/4
Y1 - 2015/4
N2 - D-dimer is the biochemical gold standard for diagnosing a variety of thrombotic disorders, but result reporting is heterogeneous in clinical laboratories. A specific five-item questionnaire was developed to gain a clear picture of the current standardization of D-dimer test results. The questionnaire was opened online (December 24, 2014-February 10, 2015) on the platform "Google Drive (Google Inc., Mountain View; CA)," and widely disseminated worldwide by newsletters and alerts. A total of 409 responses were obtained during the period of data capture, the largest of which were from Italy (136; 33%), Australia (55; 22%), Croatia (29; 7%), Serbia (26; 6%), and the United States (21; 5%). Most respondents belonged to laboratories in general hospitals (208; 51%), followed by laboratories in university hospitals (104; 26%), and the private sector (94; 23%). The majority of respondents (i.e., 246; 60%) indicated the use of fibrinogen equivalent unit for expressing D-dimer results, with significant heterogeneities across countries and health care settings. The highest prevalence of laboratories indicated they were using "ng/mL" (139; 34%), followed by "mg/L" (136; 33%), and "µg/L" (73; 18%), with significant heterogeneity across countries but not among different health care settings. Expectedly, the vast majority of laboratories (379; 93%) declared to be using a fixed cutoff rather than an age-adjusted threshold, with no significant heterogeneity across countries and health care settings. The results of this survey attest that at least 28 different combinations of measurement units are currently used to report D-dimer results worldwide, and this evidence underscores the urgent need for more effective international joined efforts aimed to promote a worldwide standardization of D-dimer results reporting.
AB - D-dimer is the biochemical gold standard for diagnosing a variety of thrombotic disorders, but result reporting is heterogeneous in clinical laboratories. A specific five-item questionnaire was developed to gain a clear picture of the current standardization of D-dimer test results. The questionnaire was opened online (December 24, 2014-February 10, 2015) on the platform "Google Drive (Google Inc., Mountain View; CA)," and widely disseminated worldwide by newsletters and alerts. A total of 409 responses were obtained during the period of data capture, the largest of which were from Italy (136; 33%), Australia (55; 22%), Croatia (29; 7%), Serbia (26; 6%), and the United States (21; 5%). Most respondents belonged to laboratories in general hospitals (208; 51%), followed by laboratories in university hospitals (104; 26%), and the private sector (94; 23%). The majority of respondents (i.e., 246; 60%) indicated the use of fibrinogen equivalent unit for expressing D-dimer results, with significant heterogeneities across countries and health care settings. The highest prevalence of laboratories indicated they were using "ng/mL" (139; 34%), followed by "mg/L" (136; 33%), and "µg/L" (73; 18%), with significant heterogeneity across countries but not among different health care settings. Expectedly, the vast majority of laboratories (379; 93%) declared to be using a fixed cutoff rather than an age-adjusted threshold, with no significant heterogeneity across countries and health care settings. The results of this survey attest that at least 28 different combinations of measurement units are currently used to report D-dimer results worldwide, and this evidence underscores the urgent need for more effective international joined efforts aimed to promote a worldwide standardization of D-dimer results reporting.
KW - Blood Chemical Analysis/methods
KW - Fibrin Fibrinogen Degradation Products/analysis
KW - Fibrinogen/chemistry
KW - Humans
KW - International Cooperation
KW - Reproducibility of Results
KW - Surveys and Questionnaires
KW - Thrombosis/blood
KW - United States
KW - Venous Thromboembolism/blood
U2 - 10.1055/s-0035-1549092
DO - 10.1055/s-0035-1549092
M3 - Article
C2 - 25839870
SN - 0094-6176
VL - 41
SP - 287
EP - 293
JO - Seminars in Thrombosis and Hemostasis
JF - Seminars in Thrombosis and Hemostasis
IS - 3
ER -