Localiser radiographs in CT: Current practice, radiation dose, image quality and clinical applications

Research output: Contribution to journalReview articlepeer-review

80 Downloads (Pure)

Abstract

Introduction: Survey or localiser radiographs are integral to CT imaging. However, the diverse functions and roles of the localiser radiograph are often obscure to radiographers and radiologists. This scoping review reports the full scope of localiser radiograph use and function in contemporary CT imaging. Methods: A scoping review was performed. A systematic literature search was conducted using four databases: MEDLINE, CINAHL, Emcare and Scopus from January 2013 to December 2023. Data extraction was conducted by two review authors and validated by a third reviewer. Thirty-six studies were included in this review. Results: Three major themes emerged: radiation dose management, image quality considerations and clinical protocol applications. Specifically, the number, order of selection and directions of localiser radiographs significantly impact patient dose and image quality; which are additionally impacted by off-centre patient positioning, which can influence the accuracy of body size estimates and CT numbers. Finally, the optimal selection of localiser radiographs, including exposure parameters (kVp, mAs), can be a part of clinical task-based imaging protocol optimisation. Conclusions: The utilities of localiser radiographs in CT imaging are varied. It is salient that radiographers and radiologists understand their role and the impacts of poor application to ensure that radiation dose is minimised and image quality maximised through correct use. Radiographers and radiologists should also be aware of the impact of poor patient positioning on ACTM function, dose and image quality. Additionally, localiser radiographs should be used for clinical task-based protocol optimisation. Implications for practice: The number, order of selection, direction, patient off-centring, and exposure parameters must be considered when utilising localiser radiographs as they impact dose, image quality, and protocol applications. It is essential for radiographers and radiologists to understand these impacts.

Original languageEnglish
Pages (from-to)1546-1555
Number of pages10
JournalRadiography
Volume30
Issue number6
DOIs
Publication statusPublished - Oct 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Localiser radiographs in CT: Current practice, radiation dose, image quality and clinical applications'. Together they form a unique fingerprint.

Cite this