T1 - Polypyrrole based amperometric and potentiometric phosphate biosensors
T2 - A comparative study
AU - Lawal, Abdulazeez T.
AU - Adeloju, Samuel B.
PY - 2012/3/28
Y1 - 2012/3/28
N2 - The preparation of two electrochemical (potentiometric and amperometric) phosphate biosensors is described and compared. Purine Nucleoside Phosphorylase (PNP) and xanthine oxidase (XOD) were co-immobilised via entrapment into polypyrrole (PPy) films by galvanostatic polymerization. Polypyrrole entrapment was achieved with 0.5 M pyrrole by using a polymerisation time of 200 sec and a mole ratio of 1:8 (6.2 U mL-1 XOD: 49.6 U mL-1 PNP) inboth biosensors. Sensitive amperometric measurements were compared with those of potentiometric measurements obtained for PPy-PNP-XOD-Fe(CN)6 4- biosensors. A minimum detectable concentration of 1.0 μM phosphate and a linear concentration range of 5-20 μM were achieved with potentiometric PPy-PNP-XOD-Fe(CN)6 4- biosensor. In comparison, a minimum detectable concentration of 10 μM and a linear concentration range of 0.1-1 mM were achieved with amperometric biosensor. The presence of uric and ascorbic acids had the least effect on the performance of the amperometric and potentiometric PPy-PNP-XOD-Fe (CN) 6 4 biosensors, therefore will not have any effect on phosphate measurement in both biosensors at levels normally present in water.
AB - The preparation of two electrochemical (potentiometric and amperometric) phosphate biosensors is described and compared. Purine Nucleoside Phosphorylase (PNP) and xanthine oxidase (XOD) were co-immobilised via entrapment into polypyrrole (PPy) films by galvanostatic polymerization. Polypyrrole entrapment was achieved with 0.5 M pyrrole by using a polymerisation time of 200 sec and a mole ratio of 1:8 (6.2 U mL-1 XOD: 49.6 U mL-1 PNP) inboth biosensors. Sensitive amperometric measurements were compared with those of potentiometric measurements obtained for PPy-PNP-XOD-Fe(CN)6 4- biosensors. A minimum detectable concentration of 1.0 μM phosphate and a linear concentration range of 5-20 μM were achieved with potentiometric PPy-PNP-XOD-Fe(CN)6 4- biosensor. In comparison, a minimum detectable concentration of 10 μM and a linear concentration range of 0.1-1 mM were achieved with amperometric biosensor. The presence of uric and ascorbic acids had the least effect on the performance of the amperometric and potentiometric PPy-PNP-XOD-Fe (CN) 6 4 biosensors, therefore will not have any effect on phosphate measurement in both biosensors at levels normally present in water.
KW - Amperometric detection
KW - Biosensor
KW - Phosphate
KW - Polypyrrole
KW - Potentiometric detection
UR - http://www.scopus.com/inward/record.url?scp=84858754525&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84858754525&partnerID=8YFLogxK
U2 - 10.3923/jas.2012.315.325
DO - 10.3923/jas.2012.315.325
M3 - Article
AN - SCOPUS:84858754525
VL - 12
SP - 315
EP - 325
JO - American Journal of Applied Sciences
JF - American Journal of Applied Sciences
SN - 1546-9239
IS - 4
ER -