TY - JOUR
T1 - Towards 50 years of platelet function analyser (PFA) testing
AU - Favaloro, Emmanuel J
AU - Pasalic, Leonardo
AU - Lippi, Giuseppe
N1 - Publisher Copyright:
© 2022 Walter de Gruyter GmbH, Berlin/Boston.
PY - 2023/4/25
Y1 - 2023/4/25
N2 - The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models-the original PFA-100 and the contemporary PFA-200. The instruments have 'identical' output, being a 'closure time' (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and "Innovance PFA P2Y" (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.
AB - The platelet function analyser (PFA) is a prevalent platelet function screening instrument, and comes in two models-the original PFA-100 and the contemporary PFA-200. The instruments have 'identical' output, being a 'closure time' (CT). Moreover, normal reference ranges provided by the manufacturer, for the specific test cartridges, are the same for both models. There are three different types of test cartridge: collagen/epinephrine (C/Epi), collagen/adenosine diphosphate (C/ADP), and "Innovance PFA P2Y" (only available in certain geographical locations). The PFA-100 was released in the mid 1990s, and so is approaching 50 years of age. The PFA-200, released in some locations in the mid 2010s, is destined to eventually replace the PFA-100, but is not yet available in the USA. The test system is highly sensitive to von Willebrand disease (VWD; C/Epi and C/ADP) and to aspirin therapy (C/Epi only), but only has moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. Accordingly, recommendations for use for screening platelet function vary according to user experience. Some workers have alternatively used the PFA to assess thrombosis risk or pre-operative bleeding risk. In this review, we provide an overview of the history of PFA, and summarise its current clinical utility.
KW - in vitro bleeding time
KW - PFA-100
KW - PFA-200
KW - platelet function analyser
UR - http://www.scopus.com/inward/record.url?scp=85135182587&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85135182587&partnerID=8YFLogxK
U2 - 10.1515/cclm-2022-0666
DO - 10.1515/cclm-2022-0666
M3 - Review article
C2 - 35859143
SN - 1434-6621
VL - 61
SP - 851
EP - 860
JO - Clinical Chemistry and Laboratory Medicine
JF - Clinical Chemistry and Laboratory Medicine
IS - 5
ER -